產品名稱:220KV變電線(xian)路接地線(xian)/攜帶型短路接地線(xian)
產品型號:
產品特點:220KV變電(dian)(dian)線(xian)(xian)(xian)(xian)路接(jie)(jie)地(di)線(xian)(xian)(xian)(xian)/攜帶型(xing)短路接(jie)(jie)地(di)線(xian)(xian)(xian)(xian),防止相鄰高壓線(xian)(xian)(xian)(xian)路或(huo)(huo)設(she)(she)(she)備(bei)(bei)對停(ting)電(dian)(dian)線(xian)(xian)(xian)(xian)路或(huo)(huo)設(she)(she)(she)備(bei)(bei)產生(sheng)(sheng)感應(ying)電(dian)(dian)壓對人體造成(cheng)危(wei)害(hai),或(huo)(huo)停(ting)電(dian)(dian)檢(jian)修設(she)(she)(she)備(bei)(bei)或(huo)(huo)線(xian)(xian)(xian)(xian)路可能產生(sheng)(sheng)感應(ying)電(dian)(dian)壓對人體造成(cheng)危(wei)害(hai),應(ying)將停(ting)電(dian)(dian)檢(jian)修線(xian)(xian)(xian)(xian)路或(huo)(huo)設(she)(she)(she)備(bei)(bei)的有(you)關(guan)部位用接(jie)(jie)地(di)線(xian)(xian)(xian)(xian)臨時(shi)接(jie)(jie)地(di)。在停(ting)電(dian)(dian)后的設(she)(she)(she)備(bei)(bei)上作(zuo)業時(shi),應(ying)用接(jie)(jie)地(di)線(xian)(xian)(xian)(xian)將設(she)(she)(she)備(bei)(bei)上的剩余電(dian)(dian)荷(he)用臨時(shi)接(jie)(jie)地(di)線(xian)(xian)(xian)(xian)放(fang)掉,也就是釋(shi)放(fang)殘余電(dian)(dian)荷(he),俗稱(cheng)“放(fang)電(dian)(dian)“。
220KV變電線路接地線/攜帶型短路接地線的詳細資料:
220KV變電線路接地線/攜帶型短路接地線??簡介:
是用(yong)于電力行業(ye)斷電后使用(yong)的一種臨時(shi)性高(gao)(gao)壓(ya)接(jie)(jie)地線(xian)(xian),就是直接(jie)(jie)連接(jie)(jie)大地的線(xian)(xian),也可以稱為安全(quan)回路(lu)線(xian)(xian),預(yu)防(fang)突然來電時(shi)對(dui)維修(xiu)人員的傷害而將高(gao)(gao)壓(ya)直接(jie)(jie)轉嫁(jia)給地球,算是一根生命(ming)線(xian)(xian)。有時(shi)也稱作"個人保安線(xian)(xian)"
220KV變電線路接地線/攜帶型短路接地線用途及分類:
1.當高壓線路或(huo)設備檢修時(shi),為防止突然送電,應將電源側(ce)的三相架空線或(huo)母線用接(jie)地(di)(di)線臨時(shi)接(jie)地(di)(di)。
2.防止相(xiang)鄰高(gao)壓線路(lu)或設(she)備(bei)(bei)對停(ting)電線路(lu)或設(she)備(bei)(bei)產(chan)生(sheng)感應電壓對人體(ti)造成危害(hai),或停(ting)電檢修(xiu)(xiu)設(she)備(bei)(bei)或線路(lu)可能產(chan)生(sheng)感應電壓對人體(ti)造成危害(hai),應將停(ting)電檢修(xiu)(xiu)線路(lu)或設(she)備(bei)(bei)的(de)有(you)關部位用接地線臨時接地。
3.在(zai)停電(dian)后(hou)的設備(bei)上作業(ye)時,應用接地(di)線(xian)將設備(bei)上的剩(sheng)余電(dian)荷用臨時接地(di)線(xian)放(fang)掉,也就是釋放(fang)殘余電(dian)荷,俗稱"放(fang)電(dian)"。
(1)高壓接地(di)線按照使用環(huan)境可(ke)以分(fen)為:室內母排型接地(di)線(JDX-NL)和室外線路型接地(di)線(JDX-WS)。
(2)高(gao)壓(ya)接(jie)(jie)(jie)(jie)地(di)線按照(zhao)電(dian)壓(ya)等(deng)級可分為:10KV接(jie)(jie)(jie)(jie)地(di)線,35KV高(gao)壓(ya)接(jie)(jie)(jie)(jie)地(di)線,110KV接(jie)(jie)(jie)(jie)地(di)線,220KV高(gao)壓(ya)接(jie)(jie)(jie)(jie)地(di)線,500KV高(gao)壓(ya)接(jie)(jie)(jie)(jie)地(di)線
(3)接地線所需要的絕緣操作桿長度按照尺寸(百鼎電氣提供)劃定如下:
380v接地線(xian)、500v接地線(xian),6kv接地線(xian),操作棒長度50CM
10KV接地線操作(zuo)棒長度長度1米
35KV接地(di)線絕緣(yuan)操(cao)作棒長度1.5米
110KV接地線絕緣操作棒長度2米(mi)
220KV接地線絕緣操作(zuo)棒長(chang)度2.5米
500KV接地線絕緣操作棒長度8米(mi)
220KV變電線路接地線/攜帶型短路接地線注意事項:
(1)掛(gua)接(jie)(jie)地(di)線時:先(xian)連結接(jie)(jie)地(di)夾,后(hou)接(jie)(jie)接(jie)(jie)電夾;拆除接(jie)(jie)地(di)線時,必須按程序先(xian)拆接(jie)(jie)電夾,后(hou)拆接(jie)(jie)地(di)夾。
(2)安裝:將(jiang)接地軟銅線分相(xiang)(xiang)上(shang)雙眼銅鼻子固定在接地棒上(shang)的(de)接電夾(jia)(接電夾(jia)有(you)固定式(shi)和活動式(shi))相(xiang)(xiang)應(ying)位(wei)置上(shang),將(jiang)接地線合相(xiang)(xiang)上(shang)的(de)單眼銅鼻子固定在接地夾(jia)或地針上(shang),構成(cheng)一(yi)套完整的(de)接地線。
(3)核實接地(di)棒的電(dian)壓(ya)等(deng)級(ji)(ji)與操作設備(bei)的電(dian)壓(ya)等(deng)級(ji)(ji)是否*。
(4)確保設備(bei)或線路在斷電后使用本器具。
(5)使用過程(cheng)操(cao)作人員應該佩戴相關防護器(qi)具,比如絕緣靴,絕緣手套以及安全(quan)帽并在有專人監護的情況下進行使用。
如果你對220KV變電線路接地線/攜帶型短路接地線感興趣,想了解更詳細的產品信息,填寫下表直接與廠家聯系: |