5KVA/50KV工頻耐壓試驗變壓器的詳細資料:
5KVA/50KV工頻耐壓試驗變壓器
特性:
◆ 電壓(ya)、電流(liu)、時間、狀態信(xin)息及提示信(xin)息等數(shu)據4.7尺大屏液晶顯示,讀(du)數(shu)清(qing)晰、直觀;
◆ 全中文(wen)界面,操作簡(jian)單(dan)明了,可適應(ying)多種(zhong)應(ying)用場合;
◆ 輕觸(chu)式按(an)鍵(jian)(jian)操作(zuo),所有功能(neng)均可通過按(an)鍵(jian)(jian)設(she)定,提(ti)高了(le)產品的安(an)全(quan)性、可靠性;
◆ 全數字式校準方(fang)式,摒棄了陳舊的電位器(qi)調整,現(xian)場(chang)使用極為(wei)方(fang)便(bian),精(jing)度易于(yu)控制(此(ci)功能帶密碼保護);
◆ 按鍵直接設定試(shi)驗變壓器變比(bi)(此功能(neng)帶密(mi)碼保護(hu)),在連(lian)接不同(tong)電(dian)壓等級的(de)試(shi)驗器時,應用(yong)靈活(huo)自如,真正做到一個(ge)控(kong)制箱可與多臺變壓器相互配(pei)套;
◆ 狀態提(ti)醒功能(neng),全中文(wen)引導式操(cao)作,即使在無(wu)說(shuo)明書的情(qing)況下亦可(ke)熟練操(cao)控(kong);
◆ 試(shi)驗過(guo)程中,屏上有閃爍(shuo)的(de)高壓符號顯示,時刻(ke)提(ti)醒操作(zuo)人員注(zhu)意(yi)安全(quan);
◆ 試(shi)驗結果顯示功(gong)能,可(ke)自動判斷試(shi)驗結果(試(shi)驗通過或(huo)(huo)試(shi)驗失敗(bai)),并能可(ke)靠記錄試(shi)品過電(dian)流、閃(shan)洛或(huo)(huo)擊(ji)穿時的電(dian)壓;
◆ 試(shi)驗(yan)結果聲(sheng)音(yin)(yin)報警(jing)功能,試(shi)驗(yan)通(tong)過或試(shi)驗(yan)失敗(bai)時(shi),設(she)備會發出不同(tong)的報警(jing)聲(sheng)音(yin)(yin),試(shi)驗(yan)人員(yuan)可直接由報警(jing)聲(sheng)音(yin)(yin)辨認試(shi)驗(yan)的結果;
◆ 暫(zan)(zan)停(ting)(ting)功能,自動控制時,此功能可做到在(zai)任(ren)意點實(shi)現升壓或降壓的暫(zan)(zan)停(ting)(ting),暫(zan)(zan)停(ting)(ting)時間(jian)可由試(shi)驗(yan)人員靈活(huo)掌握,方便觀察(cha)試(shi)品狀態;
◆ 自(zi)動(dong)計時(shi)功(gong)能。自(zi)動(dong)控制時(shi),當(dang)(dang)電壓自(zi)動(dong)上升至(zhi)設(she)定值時(shi),設(she)備自(zi)動(dong)開始計時(shi),當(dang)(dang)計時(shi)時(shi)間到,顯示試驗結果,設(she)備自(zi)動(dong)回(hui)到零位;
5KVA/50KV工頻耐壓試驗變壓器
使用方法:
中(zhong)限流電(dian)阻R1應(ying)根(gen)據試驗變壓(ya)(ya)器(qi)的額定(ding)容量來選擇(ze)。如高(gao)壓(ya)(ya)側額定(ding)輸出(chu)電(dian)流在 100-300MA時(shi),可取(qu)0.5-1Ω/V(試驗電(dian)壓(ya)(ya));高(gao)壓(ya)(ya)側額定(ding)輸出(chu)電(dian)流為1A以(yi)上時(shi),可取(qu)1Ω/V(試驗電(dian)壓(ya)(ya))。常(chang)用水電(dian)陰(yin)作(zuo)為限流電(dian)阻,管于(yu)長度(du)可按150KV/m考(kao)慮,管子和粗細應(ying)具有(you)足(zu)夠的熱容量(水阻液(ye)配制方法:用蒸餾水加入適量硫(liu)酸銅配制成各種不同的陰(yin)
球間隙及保護電阻:當電壓超過球間隙整定值時(一般取試驗電壓的110%-120%)球間隙放電,對被試品起到保護作用。球間隙保護電阻可按1Ω/V(試驗電壓)選取。
在(zai)工(gong)頻耐壓(ya)(ya)(ya)試驗(yan)中,低壓(ya)(ya)(ya)側(ce)(ce)測(ce)量(liang)電(dian)(dian)(dian)壓(ya)(ya)(ya)(儀表電(dian)(dian)(dian)壓(ya)(ya)(ya))不是(shi)非常(chang)準(zhun)確的,其原(yuan)因是(shi)由于(yu)(yu)試驗(yan)變(bian)壓(ya)(ya)(ya)器(qi)(qi)存在(zai)著(zhu)漏(lou)抗,在(zai)這上個漏(lou)抗上必然(ran)存在(zai)著(zhu)壓(ya)(ya)(ya)降或(huo)容升(sheng),使試品上的電(dian)(dian)(dian)壓(ya)(ya)(ya)低于(yu)(yu)或(huo)高(gao)(gao)于(yu)(yu)低壓(ya)(ya)(ya)側(ce)(ce)測(ce)量(liang)電(dian)(dian)(dian)壓(ya)(ya)(ya)表上反映出來的電(dian)(dian)(dian)壓(ya)(ya)(ya)。工(gong)頻耐壓(ya)(ya)(ya)試驗(yan)時,被(bei)試品上的電(dian)(dian)(dian)壓(ya)(ya)(ya)高(gao)(gao)于(yu)(yu)試驗(yan)變(bian)壓(ya)(ya)(ya)器(qi)(qi)的輸(shu)出電(dian)(dian)(dian)壓(ya)(ya)(ya),也就是(shi)所(suo)謂容升(sheng)現象。感應耐壓(ya)(ya)(ya)試驗(yan)時。試驗(yan)變(bian)壓(ya)(ya)(ya)器(qi)(qi)的漏(lou)抗必須(xu)存在(zai)著(zhu)壓(ya)(ya)(ya)降。為(wei)了準(zhun)確測(ce)量(liang)被(bei)試品上所(suo)施加電(dian)(dian)(dian)壓(ya)(ya)(ya),因此常(chang)在(zai)高(gao)(gao)壓(ya)(ya)(ya)側(ce)(ce)接入RCF阻容分(fen)壓(ya)(ya)(ya)器(qi)(qi)來測(ce)量(liang)電(dian)(dian)(dian)壓(ya)(ya)(ya)。
技術參數:
◆ 電源電壓:AC220V ±10%,50Hz±1 Hz
◆ 輸入(ru)電流:0 ~ 25A
◆ 儀表電壓:0 ~ 100V (其它范圍可定制(zhi))
◆ 輸出電(dian)壓:0 ~ 250V
◆ 輸出電流(liu):0 ~ 20A
◆ 電壓(ya)測(ce)量精度:0.5 %FS ±3 字
◆ 電流測量精度(du):0.5 %FS ±3 字(zi)
◆ 計時長度(du):0 ~ 9999 S(特殊模式(shi)可于長時間工作)
◆ 使用環境:環境溫度(du)0~50 ℃ 相對濕(shi)度(du)≤85 RH
操作注意事項
(1)試驗人員應做好分工,明確相互間辦法。并有專門人監護現場安全及觀察試品狀態。
(2)被試品應清掃干凈,并干燥,以免損壞被試品和試驗帶來的誤差。
(3)對丁大型試驗,一般都應先進行空升試驗。即不接試品時升壓至試驗電壓,校對各種表計,調整間隙。
(4)升壓速度不能太快,并必須防止突然加壓。例如調壓器不在零位的突然合閘,也不能突然切斷電源,一般應在調壓器降至零位時拉閘。
(5)當電壓升至試驗電壓時,開始計時,到1min后,迅速降到1/3試驗電壓以下時,才能拉開電源。
(6)在升壓或耐壓試驗過程,如發現下列不正常情況時,應立即降壓,切斷電源,停止試驗并查明原因:①電壓表指針擺動很大;②發現絕緣燒焦或冒煙;③被試品內有不正常的聲音。
(7)耐壓試驗前后應測量絕緣電阻,檢查絕緣情況。
泄漏試驗的操作及注意事項
(1)試驗前應先檢查被試品是否停電,接地放電,一切對外連線是否擦凈。要嚴防將試驗電壓加到人工作部位上去。
(2)接好試驗裝置的接線后,應復查無誤后才可加壓。應特別注意檢查高壓設備及引線與地與操作人員的安全距離,被試品的外殼是否可靠接地,要按安全規程中所規定的內容進行試驗。
(3)對于大電容量設備應緩慢升壓,防止被試品的充電電流燒壞微安表。必要時應分級加壓,分別讀取各級電壓下微安表的穩定讀數。
(4)試驗過程,應密切監視被試品、試驗裝置、微安表,一旦發生擊穿、閃爍等異常現象應立即降壓,切斷電源,并查明原因,詳細記錄。
(5)試驗(yan)完畢,降壓,切斷電源后應將被試品(pin)及試驗(yan)裝置(zhi)本身充分放(fang)電。
如果你對5KVA/50KV工頻耐壓試驗變壓器感興趣,想了解更詳細的產品信息,填寫下表直接與廠家聯系: |
上一篇:交流耐壓試驗裝置